<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.0 20120330//EN" "JATS-journalpublishing1.dtd">
<article article-type="abstract" dtd-version="1.0" xml:lang="en" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">CC</journal-id>
<journal-id journal-id-type="nlm-ta">Cardiol Croat</journal-id>
<journal-title-group>
<journal-title>Cardiologia Croatica</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Cardiol. Croat.</abbrev-journal-title>
</journal-title-group>
<issn pub-type="ppub">1848-543X</issn>
<issn pub-type="epub">1848-5448</issn>
<publisher><publisher-name>Croatian Cardiac Society</publisher-name></publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">CC_2013_8_9_303-304</article-id>
<article-id pub-id-type="doi">10.15836/ccar.2013.303</article-id>
<article-categories><subj-group subj-group-type="heading"><subject>Extended Abstract</subject></subj-group>
</article-categories>
<title-group>
<article-title>Left ventricular 4D imaging with low radiation dose through optimised interphase registration of rotational angiography images</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes"><name><surname>Wielandts</surname><given-names>Jean-Yves</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author"><name><surname>De Buck</surname><given-names>Stijn</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author"><name><surname>Ector</surname><given-names>Joris</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author"><name><surname>Nuyens</surname><given-names>Dieter</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author"><name><surname>Maes</surname><given-names>Frederik</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author"><name><surname>Heidbuchel</surname><given-names>Hein</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib>
<aff id="aff1"><label>1</label><institution content-type="dept">Department of Cardiovascular Sciences</institution>, <institution>Catholic University of Leuven</institution>, <addr-line>Leuven</addr-line>, <country country="be">Belgium</country></aff>
<aff id="aff2"><label>2</label><institution content-type="dept">Faculty of Engineering, ESAT/PSI, Medical Image Computing</institution>, <institution>Catholic University of Leuven</institution>, <addr-line>Heverlee</addr-line>, <country country="be">Belgium</country></aff>
</contrib-group>
<author-notes>
<corresp id="cor1">Correspondence to Jean-Yves Wielandts, Department of Cardiovascular Sciences, Catholic University of Leuven, Herestraat 49, 3000 Leuven, Belgium; Phone +3216341554; E-mail: <email xlink:href="jean-yves.wielandts@uzleuven.be">jean-yves.wielandts@uzleuven.be</email></corresp></author-notes>
<pub-date date-type="pub" publication-format="electronic"><month>09</month><year>2013</year></pub-date>
<pub-date date-type="pub" publication-format="print"><month>09</month><year>2013</year></pub-date>
<volume>8</volume>
<issue>9</issue>
<fpage>303</fpage>
<lpage>304</lpage>
<permissions>
<copyright-statement>Croatian Cardiac Society</copyright-statement>
<copyright-year>2013</copyright-year>
<copyright-holder>Croatian Cardiac Society</copyright-holder>
</permissions>
<kwd-group kwd-group-type="author"><title>KEYWORDS: </title><kwd>imaging</kwd><kwd>catheter ablation</kwd><kwd>3D rotational angiography</kwd><kwd>low radiation dose</kwd><kwd>electro-anatomical mapping</kwd></kwd-group>
</article-meta>
</front>
<body>
<p>Objectives: VT ablations could benefit from dynamic 3D (i.e. 4D) visualisation of the left ventricle (LV) as roadmap for anatomy-guided procedures, e.g. by means of rotational angiography (3DRA). To limit radiation burden, low-dose, noisy 3DRA image datasets have to be used. Our aim was to develop an algorithm combining information of several cardiac phases to filter out noise, enabling accurate semi-automatic segmentation (SAS) and generation of multi-phase segmentation surfaces.</p>
<p>Methods and Results: We explored non-rigid interphase registration (IPR) using image warping and subsequent image averaging of 4 cardiac phases in low-dose 3DRA images from 5 porcine experiments, acquired with a novel protocol of slow atrial pacing. IPR parameter settings were optimized against manual delineations of the LVs using a score (Q) composed of standardised similarity measures. SAS was done for varying voxel intensity thresholds (ISO). <xref ref-type="fig" rid="fA">Figure A</xref> shows a 4D posterior view sequence of 4 LV phases constructed with and without IPR, after SAS at ISO = 0 relative to optimal ISO. Relevant structures are the apex (1), LV inflow (2), LV outflow tract (3) and posterior papillary muscle (4). Distances to the manual delineations were reduced to 3 mm for 95.6 &#x00B1; 2,7% of model surfaces (d3mm) at optimal ISO with IPR. Post-SAS IPR and non-IPR models were compared using 3 quality measures (Q; d3mm and Hausdorff Distance [HD, reflecting maximum error]). Improved quality was proven by significant increases in d3mm (illustrated in <xref ref-type="fig" rid="fB">Figure B</xref> for the experiment of <xref ref-type="fig" rid="fA">Figure A</xref>) and Q irrespective of ISO (mean increase at optimal ISO was 7.75% (95%CI 4.60-10.90, p&lt;0.0001) for d3mm and 7.57% (95%CI 4.65-10.50, p &lt; 0.0001) for Q). HD decreased significantly (-21.35%; 95%CI -18.61&#x2014;24.10, p&lt;0.0001). 4D model generating time was &#x00B1;11.5min with IPR vs. &#x00B1;22min without.</p>
<fig id="fA" position="float" fig-type="figure"><label>Figure A</label><caption><p>Post-segmentation 4D model sequence built of four cardiac phases with (blue) and without (green) use of IPR is shown for one experiment at optimal non-IPR ISO (relative ISO = 0). The four phases in the non-IPR sequence were all segmented directly from the reconstructed 3DRA images, without prior application of IPR. The significant difference in image quality can be observed. Anatomical structures that can be seen in this view of the posterior wall of the left ventricle are the apex (<xref ref-type="bibr" rid="r1"><italic>1</italic></xref>), the LV inflow tract (<xref ref-type="bibr" rid="r2"><italic>2</italic></xref>), the LV outflow tract (<xref ref-type="bibr" rid="r3"><italic>3</italic></xref>) and the posterior papillary muscle (4).</p></caption><graphic xlink:href="CC_2013_8_9_303-304-fA"></graphic></fig>
<fig id="fB" position="float" fig-type="figure"><label>Figure B</label><caption><p>Distance measure indicating the percentage of distances from the post-segmentation model surface to the ground truth surface (manual delineations of the left ventricles) 3 mm (d3mm), averaged over all 4 phases (mean &#x00B1; SD), in both IPR (blue) and non-IPR (green) for the relevant relative ISO range in the experiment shown in <xref ref-type="fig" rid="fA">Figure A</xref>.</p></caption><graphic xlink:href="CC_2013_8_9_303-304-fB"></graphic></fig>
<p>Conclusions: Generating 4D LV models is feasible, with clinically useful accuracy, using a novel image acquisition protocol and non-rigid IPR to reduce image noise and speed up 4D image generation. Due to the use of low dose acquisition protocols, radiation dose can be kept at a clinically acceptable low level. By using slow atrial pacing, the risk of inducing unwanted ventricular tachy-arrhythmias is minimised. These findings open the perspective of realising a 4D image sequence for more accurate integration with electro- anatomical mapping systems or per-procedural fluoroscopy to facilitate ablation in locations with high degrees of movement (like the LV). (<xref ref-type="bibr" rid="r1"><italic>1</italic></xref>-<xref ref-type="bibr" rid="r3"><italic>3</italic></xref>) (<xref ref-type="fig" rid="fA">Figure A</xref>, <xref ref-type="fig" rid="fB">Figure B</xref>)</p>
</body>
<back>
<ref-list>
<title>Literature</title>
<ref id="r1"><label>1</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ector</surname><given-names>J</given-names></name><name><surname>De Buck</surname><given-names>S</given-names></name><name><surname>Huybrechts</surname><given-names>W</given-names></name><etal/></person-group> <article-title>Biplane three-dimensional augmented fluoroscopy as single navigation tool for ablation of atrial fibrillation: accuracy and clinical value.</article-title> <source>Heart Rhythm</source>. <year>2008</year>;<volume>5</volume>:<fpage>957</fpage>&#x2013;<lpage>64</lpage>. <pub-id pub-id-type="doi">10.1016/j.hrthm.2008.03.024</pub-id><pub-id pub-id-type="pmid">18598948</pub-id></mixed-citation></ref>
<ref id="r2"><label>2</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Knecht</surname><given-names>S</given-names></name><name><surname>Wright</surname><given-names>M</given-names></name><name><surname>Akrivakis</surname><given-names>S</given-names></name><etal/></person-group> <article-title>Prospective randomized comparison between the conventional electroanatomical system and three-dimensional rotational angiography during catheter ablation for atrial fibrillation.</article-title> <source>Heart Rhythm</source>. <year>2010</year>;<volume>7</volume>:<fpage>459</fpage>&#x2013;<lpage>65</lpage>. <pub-id pub-id-type="doi">10.1016/j.hrthm.2009.12.020</pub-id><pub-id pub-id-type="pmid">20159045</pub-id></mixed-citation></ref>
<ref id="r3"><label>3</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>De Buck</surname><given-names>S</given-names></name><name><surname>Alzand</surname><given-names>BS</given-names></name><name><surname>Wielandts</surname><given-names>JY</given-names></name><etal/></person-group> <article-title>Cardiac three-dimensional rotational angiography can be performed with low radiation dose while preserving image quality.</article-title> <source>Europace</source>. <year>2013</year>; <comment>[Epub ahead of print]</comment> <pub-id pub-id-type="doi">10.1093/europace/eut140</pub-id><pub-id pub-id-type="pmid">23729405</pub-id></mixed-citation></ref>
</ref-list>
</back>
</article>