<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.0 20120330//EN" "JATS-journalpublishing1.dtd">
<article article-type="abstract" dtd-version="1.0" xml:lang="en" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">CC</journal-id>
<journal-id journal-id-type="nlm-ta">Cardiol Croat</journal-id>
<journal-title-group>
<journal-title>Cardiologia Croatica</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Cardiol. Croat.</abbrev-journal-title>
</journal-title-group>
<issn pub-type="ppub">1848-543X</issn>
<issn pub-type="epub">1848-5448</issn>
<publisher><publisher-name>Croatian Cardiac Society</publisher-name></publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">CC 2026 21_11-12_401</article-id>
<article-id pub-id-type="doi">10.15836/ccar2026.401</article-id>
<article-categories><subj-group subj-group-type="heading"><subject>Extended Abstract</subject></subj-group>
<subj-group subj-group-type="subheading"><subject>Arrhythmias</subject></subj-group>
</article-categories>
<title-group>
<article-title>Optimization of a CRT-D device due to T-wave oversensing and phrenic nerve stimulation: a case report</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0009-0004-8530-9230</contrib-id><name><surname>Drlja&#x010D;i&#x0107;</surname><given-names>Magdalena</given-names></name><xref ref-type="corresp" rid="cor1">*</xref></contrib>
<contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-7557-9358</contrib-id><name><surname>Pejkovi&#x0107;</surname><given-names>Senka</given-names></name></contrib>
<contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-1878-0880</contrib-id><name><surname>Benko</surname><given-names>Ivica</given-names></name></contrib>
<contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0009-0009-5342-752X</contrib-id><name><surname>Jozi&#x0107;</surname><given-names>Nikolina</given-names></name></contrib>
<contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0009-0004-9189-5432</contrib-id><name><surname>Valjak</surname><given-names>Nikolina</given-names></name></contrib>
<contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-7381-0691</contrib-id><name><surname>Pai&#x0107;</surname><given-names>Zrinka</given-names></name></contrib>
<contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0009-0003-4660-9049</contrib-id><name><surname>Bani&#x010D;ek</surname><given-names>Klementina</given-names></name></contrib>
<contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-5610-6259</contrib-id><name><surname>Jordan</surname><given-names>Ana</given-names></name></contrib>
<aff id="aff1"><institution>Dubrava University Hospital</institution>, <addr-line>Zagreb</addr-line>, <country country="hr">Croatia</country></aff>
</contrib-group>
<author-notes>
<corresp id="cor1"><label>*</label>ADDRESS FOR CORRESPONDENCE: Magdalena Drlja&#x010D;i&#x0107;, Klini&#x010D;ka bolnica Dubrava, Avenija Gojka &#x0160;u&#x0161;ka 6, HR-10000, Zagreb, Croatia. / Phone: +385-1-290-2545 / E-mail: <email xlink:href="magdalena.drljacic@gmail.com">magdalena.drljacic@gmail.com</email></corresp></author-notes>
<pub-date date-type="pub" publication-format="electronic"><month>11</month><year>2026</year></pub-date>
<pub-date date-type="pub" publication-format="print"><month>11</month><year>2026</year></pub-date>
<volume>21</volume>
<issue>11-12</issue>
<fpage>401</fpage>
<lpage>401</lpage>
<history>
<date date-type="received"><day>20</day><month>10</month><year>2026</year></date>
<date date-type="rev-recd"><day>04</day><month>11</month><year>2026</year></date>
</history>
<permissions>
<copyright-statement>Croatian Cardiac Society</copyright-statement>
<copyright-year>2026</copyright-year>
<copyright-holder>Croatian Cardiac Society</copyright-holder>
</permissions>
<kwd-group kwd-group-type="author"><title>KEYWORDS: </title><kwd>cardiac implantable electronic device</kwd><kwd>T-wave oversensing</kwd><kwd>phrenic nerve stimulation</kwd><kwd>nursing</kwd></kwd-group>
</article-meta>
</front>
<body>
<p><bold>Introduction:</bold> Outpatient interrogation of cardiac implantable electronic devices is an essential component of long-term patient care. Periodic follow-up aims to ensure patient safety, optimal device function, and battery longevity. Device assessment is performed non-invasively through telemetry, with analysis of stored events and testing of selected parameters.</p>
<p><bold>Case report:</bold> 65-year-old woman with ischemic cardiomyopathy, secondary left ventricular dilatation, heart failure with reduced ejection fraction (HFrEF, LVEF 15%), moderate-to-severe mitral regurgitation, arterial hypertension, type 2 diabetes mellitus, hypothyroidism, and an implanted cardiac resynchronization therapy-defibrillator (CRT-D) presented for routine follow-up at the arrhythmia clinic. She reported intermittent upper abdominal discomfort and occasional &#x201C;hiccups,&#x201D; both dependent on upper-body position. Device interrogation revealed T-wave oversensing, with several dozen device-detected non-sustained ventricular tachycardia episodes attributable to oversensing. The ventricular sensing threshold was adjusted from 0.3 to 0.45 mV, after which oversensing was no longer observed. Testing also demonstrated symptomatic phrenic nerve stimulation. The left ventricular pacing configuration was changed from the LV1&#x2013;LV2 to the LV2&#x2013;LV3 vector, providing an acceptable pacing threshold without phrenic nerve stimulation even at maximum output and resulting in a 30 ms narrowing of the QRS complex on a 12-lead ECG. All other tested device parameters were within normal limits.</p>
<p><bold>Conclusion:</bold> This case highlights the complexity of CRT-D follow-up and the importance of timely recognition and response. T-wave oversensing may lead to inappropriate tachyarrhythmia detection and inappropriate implantable cardioverter defibrillator (ICD) therapy, including shocks, with potential adverse effects on patient safety, quality of life, and psychological well-being. Phrenic nerve stimulation may also cause considerable discomfort and require programming optimization. Comprehensive clinical education of nurses involved in cardiac implantable electronic device (CIED) follow-up should therefore extend beyond recording device parameters to understanding device function, recognizing abnormalities, and ensuring timely escalation and intervention. (<xref ref-type="bibr" rid="r1"><italic>1</italic></xref>-<xref ref-type="bibr" rid="r3"><italic>3</italic></xref>)</p>
</body>
<back>
<ref-list>
<title>LITERATURE</title>
<ref id="r1"><label>1</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Glikson</surname><given-names>M</given-names></name><name><surname>Nielsen</surname><given-names>JC</given-names></name><name><surname>Kronborg</surname><given-names>MB</given-names></name><name><surname>Michowitz</surname><given-names>Y</given-names></name><name><surname>Auricchio</surname><given-names>A</given-names></name><name><surname>Barbash</surname><given-names>IM</given-names></name><etal/><collab>ESC Scientific Document Group</collab></person-group>. <article-title>2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy.</article-title> <source>Eur Heart J</source>. <year>2021</year> September 14;<volume>42</volume>(<issue>35</issue>):<fpage>3427</fpage>&#x2013;<lpage>520</lpage>. <pub-id pub-id-type="doi">10.1093/eurheartj/ehab364</pub-id><pub-id pub-id-type="pmid">34455430</pub-id></mixed-citation></ref>
<ref id="r2"><label>2</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Strik</surname><given-names>M</given-names></name><name><surname>Ploux</surname><given-names>S</given-names></name><name><surname>Eschalier</surname><given-names>R</given-names></name><name><surname>Mondoly</surname><given-names>P</given-names></name><name><surname>Fontagne</surname><given-names>L</given-names></name><name><surname>Ramirez</surname><given-names>FD</given-names></name><etal/></person-group> <article-title>T-Wave oversensing with contemporary implantable cardioverter-defibrillators.</article-title> <source>J Cardiovasc Dev Dis</source>. <year>2023</year> October 17;<volume>10</volume>(<issue>10</issue>):<fpage>430</fpage>. <pub-id pub-id-type="doi">10.3390/jcdd10100430</pub-id><pub-id pub-id-type="pmid">37887877</pub-id></mixed-citation></ref>
<ref id="r3"><label>3</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Biffi</surname><given-names>M</given-names></name><name><surname>Exner</surname><given-names>DV</given-names></name><name><surname>Crossley</surname><given-names>GH</given-names></name><name><surname>Ramza</surname><given-names>B</given-names></name><name><surname>Coutu</surname><given-names>B</given-names></name><name><surname>Tomassoni</surname><given-names>G</given-names></name><etal/></person-group> <article-title>Occurrence of phrenic nerve stimulation in cardiac resynchronization therapy patients: the role of left ventricular lead type and placement site.</article-title> <source>Europace</source>. <year>2013</year> January;<volume>15</volume>(<issue>1</issue>):<fpage>77</fpage>&#x2013;<lpage>82</lpage>. <pub-id pub-id-type="doi">10.1093/europace/eus237</pub-id><pub-id pub-id-type="pmid">22848075</pub-id></mixed-citation></ref>
</ref-list>
</back>
</article>
